These error messages might appear on the system console or LCD when the system is operating, when it has halted, or when it is restarting because of system problems. These errors are generated by sensors in the appliance that constantly monitor heat, power, and other environment characteristics while the system is operating.
The following table specifies the sensor names displayed in the error messages.
The following table describes the operational error messages that might appear on the C2100 appliance LCD or on the C1200 console, if the appliance encounters errors during operation.
n--The RAID group disk number. The solution depends on whether you have a hot spare in the system--C2100 only. |
See the System Administration Guide for information about how to locate a disk based on the RAID group disk number and how to replace a faulty disk. |
|
One of the power supply units is turned off, was removed from the appliance, or failed. |
Verify that both power supplies are installed and turned on. If you still get this error, replace the power supplies one at a time to determine the failed power supply. |
|
Write down the system crash message on the system console and report the problem to Network Appliance Customer Support. |
||
A disk error occurred as you were hot swapping a disk--C2100 only. |
||
The system cannot dump core during a system crash and restarts without dumping core. |
||
The system is crashing. If the system does not hang while crashing, the message Dumping core appears. |
||
The temperature sensor indicates that the system temperature is too high. |
Verify that the ventilation holes on the top cover of the system are not blocked. If the ventilation holes are not blocked and the problem persists, contact Network Appliance Customer Support for help. |
|
A fan is back to normal condition from a warning or critical condition. |
||
One or more fans are spinning below the noncritical limit but within the critical limit. The fan might fail soon. |
||
Fan %n is in Critical State; Replace the fan immediately to avoid overheating!! |
One fan, other than the power supply fan, is spinning below the critical limit. |
Replace the fan, as described in Replacing the fans. |
Emergency shutdown: Fan failure. Replace the failed fans immediately. |
The power supply fan or two of four fans (three system fans and one processor fan) are spinning below the critical limit. The system will be shut down--C2100 only. Two of five system fans are spinning below the critical limit. System will be shut down--C1200 only. |
|
A temperature is back to a normal condition from a warning or critical condition |
||
System temperature <high/low> warning: sensor Temperature %a |
A temperature is outside the noncritical limit but within the critical limit. |
Adjust the temperature of the room where the system is located. |
Emergency Shutdown: System too <hot/cold>: sensor Temperature %a |
A temperature is outside the critical limit. The system shuts down when it reaches this limit. |
|
A power voltage is back to a normal condition from a warning or critical condition. |
||
Power %a outside normal functioning voltage levels but within critical range |
A power voltage is outside noncritical limits but within critical limits. |
If the condition persists, replace the identified power supply, as described in Replacing the power supplies. |
Power %a POWER SUPPLY FAILED!! Shutting down the system because of Power %a POWER SUPPLY FAILED!! |
A power voltage is outside the critical limit. The system shuts down. |
Replace the power supply, as described in Replacing the power supplies. |
Check the power supply for the failed conditions, then replace it, as described in Replacing the power supplies, if needed. |
||
One of the following events was detected at the power unit sensor: |
Check the power and correct any conditions or replace the power supply, as described in Replacing the power supplies. |
|
One of the following events was detected at the power unit redundancy sensor: |
||
See Startup error messages for information about the displayed error. |
||
One of the following events was detected at the memory sensor: |
||
One of the following events was detected at the SCSI voltage performance sensor: |
||
One of the following events was detected at the processor sensor: |
||
One of the following events was detected at the DIMMn (n = 1-6) sensor: |
Replace the identified DIMM, if faulty, as described in Replacing the DIMMs in the appliance. |
|
One of the following events was detected at the sensor failure sensor: |
Replace the motherboard, as described in Replacing the motherboard. |
Copyright © 1994-2002, Network Appliance, Inc. All rights
reserved.
Part No. 210-00378
File: ch5_err5.htm
Last updated: 11/13/02 12:34:22