The power supply fan is integrated into the power supply chassis. If the power supply fan fails, you must replace the power supply chassis. To remove the power supply chassis from the C2100, complete the following steps, using the figure for reference.
| 1 | Open the appliance, as described in Opening the appliance. |
| 2 | Remove both power supplies, as described in Removing a power supply from the C2100. |
| 3 | Remove the ATA Flex cable retaining bracket, located on the backplane, then disconnect the copper-colored ATA Flex cable from the SCSI backplane. |
| 4 | Remove the cooling fan block, as described inReplacing chassis fans. |
| 5 | Remove the two screws on the back of the power supply chassis, then remove the inside screw that secures the power supply chassis to the C2100 chassis. |
| 6 | Disconnect the cables running from the back of the power supply chassis, then slide the power supply chassis toward the front of the appliance and lift it out of the C2100 chassis. |
To install a power supply chassis, complete the following steps.
| 1 | Lower the new power supply cage into place in the appliance, then slide it toward the back of the appliance. |
| 2 | Secure the power supply cage to the chassis with the three screws that you removed in Step 5 of Removing the power supply chassis on the C2100. |
| 3 | Reconnect the cables running from the back of the power supply cage to the motherboard. |
| 4 | Reinstall the chassis fan assembly, as described in Replacing chassis fans. |
| 5 | Reconnect the copper-colored ATA Flex cable to the SCSI backplane, then reattach the ATA Flex cable retaining bracket to the backplane. |
| 6 | Slide the two power supplies into the power supply cage, and lock them into place. |
| 7 | Close the appliance, as described in Closing the appliance. |