Boot error messages might appear after the hardware passes all POSTs and the C3100/C6100 begins to load the operating system.
The following table describes the error messages that might appear on the LCD if the C3100/C6100 encounters errors while starting up.
Boot error message
|
Explanation
|
Fatal?
|
Corrective action
|
No /etc/rc
|
The /etc/rc file is corrupted.
|
No
|
- At the hostname> prompt,
enter setup.
- As the system prompts for
system configuration
information, use the
information you recorded in
the C3100/C6100
configuration information
worksheet in the Getting
Started Guide.
For more information about the C3100/C6100 setup program, see the NetCache Appliance Administrator's Guide.
|
No /etc/rc, running setup
|
The system cannot find the /etc/rc file and automatically starts setup.
|
No
|
As the system prompts for system configuration information, use the information you recorded in the C3100/C6100 configuration information worksheet in the Getting Started Guide.
For more information about the C3100/C6100 setup program, see the NetCache Appliance Administrator's Guide.
|
Cannot initialize labels
|
When the system tries to create a new file system, it cannot initialize the disk labels.
|
Yes
|
Usually, you do not need to create and initialize a file system; do so only after consulting Network Appliance Technical Support.
|
Cannot read labels
|
When the C3100/C6100 tries to initialize a new file system, it has a problem reading the disk labels it wrote to the disks.
This problem might be because
- The system fails to read the disk size
- The written disk labels were invalid
|
Yes
|
Usually, you do not need to create and initialize a file system; do so only after consulting Network Appliance Technical Support.
|
Disk label processing failed
|
The C3100/C6100 detects that the disk is not in the correct drive bay.
|
Yes
|
Make sure that the disk is in the correct bay.
|
Dirty shutdown in degraded mode
|
The file system is inconsistent because you did not shut down the system cleanly when it was in degraded mode.
|
Yes
|
Contact Network Appliance Technical Support for instructions about repairing the file system.
|
No disk controllers
|
The system cannot detect any FC-AL disk controllers.
|
Yes
|
Turn off the power on the C3100/C6100 and verify that all NICs are properly seated in the appropriate expansion slots.
|
No disks
|
The system cannot detect any FC-AL disks.
|
Yes
|
Verify that all disks are properly seated in the drive bays.
|
Drive %s.%d not supported
|
%s--The FC-AL disk number. %d--The disk ID number. The system detects an unsupported disk drive.
|
Yes
|
- Remove the drive
immediately or the system
drops down to the PROM
monitor within 30 seconds.
- Check the System
Configuration Guide at
http://now.netapp.com to
verify support for your disk
drive.
|
FC-AL loop down, adapter %d
|
The system cannot detect the FC-AL loop or adapter.
|
Yes
|
- Identify the adapter by
entering the following
command:
diskInfo.HostAdapter
- Turn off the power on the
C3100/C6100 and verify that
the adapter is properly seated
in the expansion slot.
- Verify that all Fibre Channel
cables are connected.
|
File system might be scrambled
|
One of the following errors causes the file system to be inconsistent:
|
|
|
- An unclean shutdown when the C3100/C6100 is in degraded mode and when NVRAM is not working.
|
Yes
|
Contact Network Appliance Technical Support to learn how to start the system from a system boot diskette and repair the file system.
|
- The number of disks detected in the disk array is different from the number of disks recorded in the disk labels. The system cannot start when more than one disk is missing.
|
Yes
|
Make sure that all disks on the system are properly installed in the disk shelves.
|
- The system encounters a read error while reconstructing parity.
|
Yes
|
Contact Network Appliance Technical Support for help.
|
- A disk failed at the same time the system crashed.
|
Yes
|
Contact Network Appliance Technical Support to learn how to repair the file system.
|
Invalid PCI card slot %d
|
%d--The expansion slot number. The system detects an adapter that is not supported by Network Appliance.
|
Yes
|
Replace the unsupported adapter with an adapter that is included in the System Configuration Guide at http://now.netapp.com.
|
Configuration exceeds max PCI space
|
The memory space for mapping PCI adapters has been exhausted, because either
- There are too many PCI adapters are in the system
- An adapter is demanding too many resources
|
Yes
|
Verify that all expansion adapters in the C3100/C6100 are supported.
Contact Network Appliance Technical Support for help. Have a list ready of all expansion adapters installed in the C3100/C6100.
|
No network interfaces
|
The system cannot detect any network interfaces.
|
Yes
|
Turn off the system and verify that all NICs are seated properly in the appropriate expansion slots.
If the problem persists, contact Network Appliance Technical Support.
|
No NVRAM present
|
The system cannot detect the NVRAM adapter.
|
Yes
|
Make sure that the NVRAM adapter is securely installed in expansion slot 11.
|
Replace NVRAM battery
|
The NVRAM battery is low. The system shuts down immediately.
|
Yes
|
Replace the battery.
|
Replace %s
|
%s--The number of NVRAM batteries. The C3100/C6100 has a single NVRAM battery.
|
Yes
|
Replace the battery.
|
NVRAM #n downrev
|
n--The serial number of the NVRAM adapter. The NVRAM adapter is an early revision that cannot be used with the system.
|
Yes
|
Check the console for information about which revision of the NVRAM adapter is required. Replace the NVRAM adapter.
|
NVRAM test failed
|
The system NVRAM produces an error when the system is starting.
|
Yes
|
Contact Network Appliance Technical Support if this message appears.
|
Unsupported NVRAM size %dMB
|
%d--The amount of memory on the NVRAM adapter. The specified size is not supported.
|
Yes
|
Verify that the system has 128 MB of NVRAM.
|