NetApp
Cluster : Storage > Aggregates : Managing aggregates : Converting an aggregate to a Flash Pool aggregate

Converting an aggregate to a Flash Pool aggregate
You can convert a non-root aggregate that is composed of HDDs to a Flash Pool aggregate by adding one or more RAID groups composed of SSDs. The SSD tier functions as a high-performance cache to the working data set, increasing the performance of the aggregate without using SSDs for the entire aggregate.
Before you begin 
•
Note: If the cluster is in a mixed-version state and some of the nodes are running Data ONTAP 8.1, you can use the command-line interface to create a Flash Pool aggregate.
•
•
•
•
About this task 
You should be aware of platform-specific and workload-specific best practices for Flash Pool aggregate SSD tier size and configuration. For more information, see Technical Report 4070: NetApp Flash Pool Design and Implementation Guide.
Steps 
1.
From the home page, double-click the appropriate storage system.
2.
Expand either the Cluster or the Nodes hierarchy in the left navigation pane.
3.
In the navigation pane, click Storage > Aggregates.
4.
Select the aggregate that you want to convert to a Flash Pool aggregate and click Edit.
5.
Select the option for enabling Flash Pool aggregate.
6.
The default value is the minimum number of cache disks that is required to create a RAID group. The default number of cache disks is 3 for RAID-DP and 2 for RAID4.
7.
Click Save and Close.
8.
Verify the changes you made to the selected aggregate in the Details tab in the Aggregates window.


Was this topic helpful? Send comments to NetApp.