Data ONTAP® PowerShell Toolkit

Switch to Data ONTAP Cluster-mode documentation.

Cmdlet: Disable-NaFcpAdapter


NAME
Disable-NaFcpAdapter

SYNOPSIS
Bring the adapter offline.

SYNTAX
Disable-NaFcpAdapter [-Adapter] <String> [-Controller <NaController>] [-What
If] [-Confirm] [<CommonParameters>]


DESCRIPTION
Bring the adapter offline. If FCP service is not running, then the adapters
are automatically offlined. The adapter may not be offline immediately afte
r the call returns, it may take up to a few seconds for the adapter to chang
e state.

Note: this cmdlet only applies to FCP target adapters. To affect all FC ada
pters, use Disable-NaFcAdapter.


PARAMETERS
-Adapter <String>
FC adapter to take offline.

Required? true
Position? 1
Default value
Accept pipeline input? true (ByValue, ByPropertyName)
Accept wildcard characters? false

-Controller <NaController>
The Data ONTAP controller object, embodied by an NaController object. T
his parameter is returned by the Connect-NaController cmdlet. If not sp
ecified, the value in the global variable CurrentNaController is used.

Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters? false

-WhatIf


Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters? false

-Confirm


Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters? false

<CommonParameters>
This cmdlet supports the common parameters: Verbose, Debug,
ErrorAction, ErrorVariable, WarningAction, WarningVariable,
OutBuffer and OutVariable. For more information, type,
"get-help about_commonparameters".

INPUTS



OUTPUTS
DataONTAP.Types.Fcp.FcpConfigAdapterInfo


NOTES


Category: fcp
API: fcp-adapter-config-down

-------------- Example 1 --------------

C:\PS>Disable-NaFcpAdapter 0c


Take FCP adapter 0c offline.


Adapter : 0c
AdapterType : Local
CacheLineSize : 16
ConnectionEstablished : loop
DataLinkRate : 0
ErrorMsg :
ExternalGbicEnabled : False
FabricEstablished : False
FirmwareRev : 4.5.2
HardwareRev : 2
InfoName : Dual-channel, QLogic 2432 (2462)
LoopId :
MediaType : auto
NodeName : 50:0a:09:80:87:09:3b:1f
PacketSize : 2048
PartnerAdapter :
PciBusWidth :
PciClockSpeed :
PortAddress : 0
PortId :
PortName : 50:0a:09:83:97:09:3b:1f
Speed : auto
SramParityEnabled : True
Standby : False
State : offlined by user/system



RELATED LINKS
Enable-NaFcpAdapter