Data ONTAP® PowerShell Toolkit

Switch to Data ONTAP 7-mode documentation.

Cmdlet: Get-NcNodeInfo


NAME
Get-NcNodeInfo

SYNOPSIS
Obtain node information which includes CPU and backplane information.

SYNTAX
Get-NcNodeInfo [[-Name] <String[]>] [-Attributes <SystemInfo>] [-Controller
<NcController[]>] [<CommonParameters>]

Get-NcNodeInfo -Template [-Controller <NcController[]>] [<CommonParameters>]

Get-NcNodeInfo -Query <SystemInfo> [-Attributes <SystemInfo>] [-Controller <
NcController[]>] [<CommonParameters>]


DESCRIPTION
Obtain node information which includes CPU and backplane information. I/O i
nformation is not included.


PARAMETERS
-Name <String[]>
The name of one or more nodes to get. Data ONTAP wildcards are permitte
d.

Required? false
Position? 1
Default value
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters? false

-Attributes <SystemInfo>
For improved scalability in large clusters, provide a SystemInfo object
with various fields set to indicate which fields to return on all object
s. Undesired fields should remain set to null. Use "Get-NcNodeInfo -Te
mplate" to get the initially empty SystemInfo object. If not specified,
all data is returned for each object.

Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters? false

-Controller <NcController[]>
A clustered Data ONTAP controller to receive this cmdlet, as embodied by
an NcController object. This parameter is returned by the Connect-NcCo
ntroller cmdlet. If not specified, the value in the global variable Cur
rentNcController is used. In the latter case, if CurrentNcController co
ntains a collection of NcController objects, this cmdlet is invoked on e
ach controller in succession.

Required? false
Position? named
Default value
Accept pipeline input? true (ByValue, ByPropertyName)
Accept wildcard characters? false

-Template
Specify to get an empty SystemInfo object for use with advanced queries
involving the Query attribute.

Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters? false

-Query <SystemInfo>
For advanced queries, provide a SystemInfo object with various fields se
t to indicate which records to retrieve. Other fields should remain set
to null. Use "Get-NcNodeInfo -Template" to get the initially empty Sys
temInfo object.

Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters? false

<CommonParameters>
This cmdlet supports the common parameters: Verbose, Debug,
ErrorAction, ErrorVariable, WarningAction, WarningVariable,
OutBuffer and OutVariable. For more information, type,
"get-help about_commonparameters".

INPUTS



OUTPUTS
DataONTAP.C.Types.System.SystemInfo


NOTES


Category: system
API: system-get-node-info-iter
Family: cluster

-------------- Example 1 --------------

C:\PS>Get-NcNodeInfo


List info about all cluster nodes.


NcController : 10.61.172.155
Name : fas3070cluster01-01
BackplanePartNumber :
BackplaneRevision :
BackplaneSerialNumber :
BoardSpeed : 1799
BoardType : System Board XII
ControllerAddress :
CpuCiobRevisionId :
CpuFirmwareRelease : 2.5.0
CpuMicrocodeVersion : 77
CpuPartNumber : 110-00112
CpuProcessorId :
CpuProcessorType : Opteron
CpuRevision : A2
CpuSerialNumber : 434736
MemorySize : 8192
NumberOfProcessors : 4
PartnerSystemId : 0118054408
PartnerSystemName : fas3070cluster01-02
PartnerSystemSerialNumber :
ProdType :
SupportsRaidArray : False
SystemId : 0118059099
SystemMachineType : FAS3070
SystemModel : FAS3070
SystemName : fas3070cluster01-01
SystemRevision : D3
SystemSerialNumber : 3091378
VendorId : NetApp
SupportsRaidArraySpecified : True

NcController : 10.61.172.155
Name : fas3070cluster01-02
BackplanePartNumber :
BackplaneRevision :
BackplaneSerialNumber :
BoardSpeed : 1800
BoardType : System Board XII
ControllerAddress :
CpuCiobRevisionId :
CpuFirmwareRelease : 2.5.0
CpuMicrocodeVersion : 77
CpuPartNumber : 110-00112
CpuProcessorId :
CpuProcessorType : Opteron
CpuRevision : A2
CpuSerialNumber : 435180
MemorySize : 8192
NumberOfProcessors : 4
PartnerSystemId : 0118059099
PartnerSystemName : fas3070cluster01-01
PartnerSystemSerialNumber :
ProdType :
SupportsRaidArray : False
SystemId : 0118054408
SystemMachineType : FAS3070
SystemModel : FAS3070
SystemName : fas3070cluster01-02
SystemRevision : D3
SystemSerialNumber : 3091379
VendorId : NetApp
SupportsRaidArraySpecified : True



RELATED LINKS
Get-NcNode







 Data ONTAP® PowerShell Toolkit