Data ONTAP® PowerShell Toolkit

Switch to Data ONTAP 7-mode documentation.

Cmdlet: Restart-NcServiceProcessor


NAME
Restart-NcServiceProcessor

SYNOPSIS
Reboot the service processor.

SYNTAX
Restart-NcServiceProcessor [-Node] <String> [[-FirmwareImage] <String>] [-Co
ntroller <NcController[]>] [<CommonParameters>]


DESCRIPTION
Reboot the service processor.


PARAMETERS
-Node <String>
Node on which the device is located.

Required? true
Position? 1
Default value
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters? false

-FirmwareImage <String>
Firmware image to boot. Default is 'primary'.
Possible values:
'primary' - Firmware which the device boots into by default,
'backup' - Firmware which the device boots into if primary fails

Required? false
Position? 2
Default value
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters? false

-Controller <NcController[]>
A clustered Data ONTAP controller to receive this cmdlet, as embodied by
an NcController object. This parameter is returned by the Connect-NcCo
ntroller cmdlet. If not specified, the value in the global variable Cur
rentNcController is used. In the latter case, if CurrentNcController co
ntains a collection of NcController objects, this cmdlet is invoked on e
ach controller in succession.

Required? false
Position? named
Default value
Accept pipeline input? true (ByValue, ByPropertyName)
Accept wildcard characters? false

<CommonParameters>
This cmdlet supports the common parameters: Verbose, Debug,
ErrorAction, ErrorVariable, WarningAction, WarningVariable,
OutBuffer and OutVariable. For more information, type,
"get-help about_commonparameters".

INPUTS



OUTPUTS
DataONTAP.C.Types.ServiceProcessor.ServiceProcessorInfo


NOTES


Category: service processor
API: service-processor-reboot
Family: cluster

-------------- Example 1 --------------

C:\PS>Restart-NcServiceProcessor -Node sfp-cmode-02-01


Rebooting the service processor on node sfp-cmode-02-01.


DeviceRevision : Not Applicable
FirmwareVersion : 2.2
IpAddress : {10.63.165.55}
IpmiVersion :
IsAutoupdateEnabled : True
IsIpConfigured : True
MacAddress : 00:a0:98:1d:3c:a4
NcController : 10.63.165.62
Node : sfp-cmode-02-01
PartNum : Not Applicable
SerialNum : Not Applicable
Status : rebooting
Type : sp
IsAutoupdateEnabledSpecified : True
IsIpConfiguredSpecified : True



RELATED LINKS
Get-NcServiceProcessor







 Data ONTAP® PowerShell Toolkit