Data ONTAP® PowerShell Toolkit

Switch to Data ONTAP 7-mode documentation.

Cmdlet: Enable-NcFcpAdapter


NAME
Enable-NcFcpAdapter

SYNOPSIS
Bring a Fibre Channel target adapter online.

SYNTAX
Enable-NcFcpAdapter [-Node] <String> [-Adapter] <String> [-Controller <NcCon
troller[]>] [<CommonParameters>]


DESCRIPTION
Bring a Fibre Channel target adapter online. The adapter may not be online i
mmediately after the call returns, it may take up to a few seconds for the a
dapter to initialize. In Data ONTAP 7-Mode, if the FCP service is not runnin
g then all adapters are automatically offlined. They cannot be brought onlin
e again until FCP service is started. In clustered Data ONTAP, offlining an
adapter will operationally disable all FCP logical interfaces (LIFs) hosted
by the adapter.


PARAMETERS
-Node <String>
The name of the storage system node where the adapter is installed.

Required? true
Position? 1
Default value
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters? false

-Adapter <String>
FC adapter to bring online.

Required? true
Position? 2
Default value
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters? false

-Controller <NcController[]>
A clustered Data ONTAP controller to receive this cmdlet, as embodied by
an NcController object. This parameter is returned by the Connect-NcCo
ntroller cmdlet. If not specified, the value in the global variable Cur
rentNcController is used. In the latter case, if CurrentNcController co
ntains a collection of NcController objects, this cmdlet is invoked on e
ach controller in succession.

Required? false
Position? named
Default value
Accept pipeline input? true (ByValue, ByPropertyName)
Accept wildcard characters? false

<CommonParameters>
This cmdlet supports the common parameters: Verbose, Debug,
ErrorAction, ErrorVariable, WarningAction, WarningVariable,
OutBuffer and OutVariable. For more information, type,
"get-help about_commonparameters".

INPUTS



OUTPUTS
DataONTAP.C.Types.Fcp.FcpConfigAdapterInfo


NOTES


Category: fcp
API: fcp-adapter-config-up
Family: cluster

-------------- Example 1 --------------

C:\PS>Enable-NcFcpAdapter VxeRubble-01 0a


Enable the FCP adapter 0a on node VxeRubble-01.


Adapter : 0a
CacheLineSize : 16
ConnectionEstablished : ptp
DataLinkRate : 4
ExternalGbicEnabled : False
FabricEstablished : True
FirmwareRev : 5.5.2
HardwareRev : 2
InfoName : Fibre Channel Target Adapter 0a (rev. 2)
MaxSpeed : 4
MediaType : ptp
MpiFirmwareRev :
Node : VxeRubble-01
NodeName : 50:0a:09:80:89:0b:bf:89
PacketSize : 2048
PciBusWidth : 64
PciClockSpeed : 33
PhyFirmwareRev :
PhysicalDataLinkRate :
PhysicalLinkState :
PhysicalProtocol : fibre_channel
PortAddress : 70912
PortName : 50:0a:09:81:89:0b:bf:89
Speed : auto
SramParityEnabled : True
State : online
SwitchPort :
VlanId :
CacheLineSizeSpecified : True
DataLinkRateSpecified : True
ExternalGbicEnabledSpecified : True
FabricEstablishedSpecified : True
PacketSizeSpecified : True
PciBusWidthSpecified : True
PciClockSpeedSpecified : True
PhysicalDataLinkRateSpecified : False
PortAddressSpecified : True
SramParityEnabledSpecified : True
VlanIdSpecified : False



RELATED LINKS
Disable-NcFcpAdapter
Get-NcFcpAdapter
Set-NcFcpAdapterSpeed







 Data ONTAP® PowerShell Toolkit