Cmdlet: Add-NaSnmpTrapHost


NAME
Add-NaSnmpTrapHost

SYNOPSIS
Adds a host to the list of trap hosts.

SYNTAX
Add-NaSnmpTrapHost [-Hosts] <String[]> [-Controller <NaController>] [<Common
Parameters>]


DESCRIPTION
Adds a host to the list of trap hosts.


PARAMETERS
-Hosts <String[]>
Specify the host(s) to be added. Host may be specified in Domain Name f
ormat such as MyHost.MyNetwork.com, or as an IP address such as 10.20.30
.40. If a Domain Name is used, the host must resolve to an IP address.

Required? true
Position? 1
Default value
Accept pipeline input? true (ByValue, ByPropertyName)
Accept wildcard characters? false

-Controller <NaController>
The Data ONTAP controller object, embodied by an NaController object. T
his parameter is returned by the Connect-NaController cmdlet. If not sp
ecified, the value in the global variable CurrentNaController is used.

Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters? false

<CommonParameters>
This cmdlet supports the common parameters: Verbose, Debug,
ErrorAction, ErrorVariable, WarningAction, WarningVariable,
OutBuffer and OutVariable. For more information, type,
"get-help about_commonparameters".

INPUTS



OUTPUTS
DataONTAP.Types.Snmp.SnmpStatusInfo


NOTES


Category: snmp
API: snmp-traphost-add

-------------- Example 1 --------------

C:\PS>Add-NaSnmpTrapHost 10.10.10.10 10.10.10.20





Communities : {DataONTAP.Types.Snmp.CommunityInfo}
Contact :
IsTrapEnabled : True
Location :
Traphosts : {x3550rre8.rtprre.testdomain, 10.10.10.10, 10.10.10.20}



RELATED LINKS
Remove-NaSnmpTrapHost
Get-NaSnmp







 Data ONTAP® PowerShell Toolkit