SnapDrive 4.1D2
Based on SnapDrive 4.1
9/28/2006

Bugs fixed in this release:

188393 - 
A timeout of 600 sec has elapsed while waiting for volume arrival 
notification.  Instead of waiting for volume arrival for up to 10 minutes,
we now look for a disk arrival event, which will timeout after 2 minutes
if unsuccessful.

194921 - 
A new storport hotfix has been release from Microsoft.  SDW4.1D1 will 
now check for and require installation of hotfix 916048, if not already
installed.
stoport.sys  5.2.3790.2723

199180 - 
During SnapManager for Exchange remote verification process in an MSCS 
configuration, system event logs will sometimes incorrectly report a 
repeated warning event 310, invalid lun path.

200386 - SnapDrive fails to Connect to SnapMirror LUNs for Exchange 
DR site when hostnames are in upper case.

201321 - SnapMirror rolling updates fail if the SnapMirror configuration 
information on the source and destination filers are different. 

202698 - SnapDrive must recognize and work with SnapMirror relationship 
created using DNS name and/or a specified network interface name.

203682 - SnapDrive 4.1D2 now requires MS Hotfix 922772, hbaapi.dll on 
W2K3 systems.  http://support.microsoft.com/?id=922772

205937 - SnapDrive 4.1D2 now requires MS Hotfix 913647, vss rollup on 
W2K3 systems.  http://support.microsoft.com/?id=913648

206429 - Allow any LUN extension usage in SDW.

208533 - During upgrade of SDW4.1Dx, if a Qlogic FCP HBA is detected, 
the vendor specific ql2xhai2.dll (2.0.0.14) will be installed.  
This dll addresses the memory leak reported in public burt 208720
(http://now.netapp.com/NOW/cgi-bin/bol?Type=Detail&Display=208720).

208705 - SnapDrive Space Reservation monitoring should generate xml 
entries for "FractionalReserved" tag if the filer version is prior to 
7.1. This fix addresses the SME 3.2 and Data ONTAP 7.0.x or earlier 
deficiency reported in public burt 206692 
(http://now.netapp.com/NOW/cgi-bin/bol?Type=Detail&Display=206692).

212397 - Optimize SnapDrive queuing of multiple commands by 
increasing queue wait time to default of 30 seconds.

94095 - SCSI Pass-Thru command directed to a non-Netapp disk may fail 
on some types of hardware, resulting in false warnings in event log 
(event 156).  